{"id":750,"date":"2025-06-20T09:19:28","date_gmt":"2025-06-20T01:19:28","guid":{"rendered":"https:\/\/preview.yhct.site\/577906b9\/?p=750"},"modified":"2025-10-22T16:59:12","modified_gmt":"2025-10-22T08:59:12","slug":"the-first-affiliated-hospital-of-chongqing-medical-university-publishes-breakthrough-research-on-patellar-stability-weightbearing-cone-beam-ct-demonstrates-significant-diagnostic-advantages","status":"publish","type":"post","link":"https:\/\/preview.yhct.site\/577906b9\/news\/the-first-affiliated-hospital-of-chongqing-medical-university-publishes-breakthrough-research-on-patellar-stability-weightbearing-cone-beam-ct-demonstrates-significant-diagnostic-advantages\/","title":{"rendered":"The First Affiliated Hospital of Chongqing Medical University Publishes Breakthrough Research on Patellar Stability: Weightbearing Cone Beam CT Demonstrates Significant Diagnostic Advantages"},"content":{"rendered":"<p><strong>Chongqing, China \u2013<\/strong>\u00a0A research team from the First Affiliated Hospital of Chongqing Medical University has published a groundbreaking study in\u00a0<em>Clinical Orthopaedics and Related Research\u00ae (CORR)<\/em>, highlighting the diagnostic superiority of weightbearing cone beam computed tomography (CBCT) in evaluating patellar stability. The study, titled\u00a0<em>\u201cDecreased Association Between Patellar Axial Malalignment and Patellar Height and Increased Association Between Patellar Axial Malalignment and Tibial Tubercle-Trochlear Groove During Weightbearing\u201d<\/em>, provides compelling evidence that WR-3D weightbearing CBCT significantly improves the accuracy of patellar malalignment assessment compared to traditional imaging methods.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-1244\" src=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/001.jpg\" alt=\"\" width=\"800\" height=\"1030\" srcset=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/001.jpg 554w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/001-233x300.jpg 233w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-1245 size-large\" src=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-795x1024.jpg\" alt=\"\" width=\"795\" height=\"1024\" srcset=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-795x1024.jpg 795w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-233x300.jpg 233w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-768x989.jpg 768w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-1193x1536.jpg 1193w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002-600x773.jpg 600w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/002.jpg 1269w\" sizes=\"(max-width: 795px) 100vw, 795px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Challenges in Diagnosing Recurrent Patellar Dislocation<\/strong><\/p>\n<p>Recurrent patellar dislocation (RPD) is a common yet complex condition in sports medicine and orthopaedics, posing diagnostic and therapeutic challenges. Early identification of anatomical abnormalities and dynamic instability is critical, yet current diagnostic approaches are limited by the complexity of etiology, lack of standardized surgical criteria, and insufficiently individualized postoperative rehabilitation.<\/p>\n<p>Traditional imaging techniques\u2014including radiographs, CT, and MRI\u2014are predominantly performed in a supine, non-weightbearing position. X-rays assess parameters such as trochlear depth (&gt;145\u00b0 indicating dysplasia), congruence angle (CA), and patellar height (Caton-Deschamps Index &gt;1.2). CT quantifies tibial tubercle\u2013trochlear groove (TT-TG) distance (&gt;20 mm is considered abnormal) to determine the need for tibial tubercle osteotomy. MRI enables detailed evaluation of medial patellofemoral ligament (MPFL) tears\u2014present in approximately 90% of acute dislocations\u2014as well as cartilage and bone bruising. However, none of these methods accurately reflect the patellofemoral joint\u2019s biomechanical status under load.<\/p>\n<p><strong>Innovative WR-3D Technology Yields Breakthrough Insights<\/strong><\/p>\n<p>In collaboration with Angell Technology\u2019s\u00a0DTP580-B3 (WR-3D)\u00a0weightbearing CBCT platform, the research team conducted a clinical study that directly addresses the limitations of conventional non-weightbearing imaging. The study found that WR-3D enables more accurate visualization of the correlation between patellar axial malalignment and TT-TG distance under physiological load, reflecting real-time muscular engagement, particularly of the quadriceps.<\/p>\n<p>This innovation provides a major leap forward in patellar instability diagnostics, allowing clinicians to observe the patella in a functional, weightbearing state\u2014offering a more comprehensive and physiologically relevant understanding than traditional supine imaging.<\/p>\n<p><strong>Significance of Weightbearing Imaging<\/strong><\/p>\n<p>The study also reveals that patellar positioning and alignment under weightbearing conditions differ significantly from those in a relaxed, supine position. This underscores the clinical importance of evaluating patients in a functional stance to better predict instability and dislocation risk. By simulating real-life joint loading conditions, WR-3D overcomes the limitations of static supine assessments and facilitates biomechanically informed decision-making.<\/p>\n<p><strong>About the Journal and Editorial Endorsement<\/strong><\/p>\n<p>The findings were published in\u00a0<em>Clinical Orthopaedics and Related Research\u00ae (CORR)<\/em>, a leading journal in orthopaedic medicine published by The Association of Bone and Joint Surgeons\u00ae. Founded in 1953, CORR covers a wide array of topics including joint surgery, sports medicine, trauma, musculoskeletal oncology, and biomechanics. The journal maintains a strong academic reputation, with a 2023 impact factor of 4.2 and a Q1 ranking in both the Orthopaedics and Surgery categories according to JCR metrics.<\/p>\n<p><strong>Study Design and Methodology<\/strong><\/p>\n<p>The research included 52 patients with recurrent patellar dislocation and 52 healthy controls, all examined between January and September 2023. Participants underwent both weightbearing CBCT and traditional CT scans. During WR-3D scanning, patients stood upright on an automated rotating platform with full knee extension and\u00a0even weight distribution.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter size-full wp-image-1247\" src=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/003.png\" alt=\"\" width=\"517\" height=\"514\" srcset=\"https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/003.png 517w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/003-300x298.png 300w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/003-150x150.png 150w, https:\/\/preview.yhct.site\/577906b9\/wp-content\/uploads\/2025\/06\/003-100x100.png 100w\" sizes=\"(max-width: 517px) 100vw, 517px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Key anatomical parameters were evaluated, including patellar height, axial malalignment (assessed via bisect offset index and tilt angle), TT-TG distance, and trochlear morphology (depth and sulcus angle). All measurements were independently conducted by two experienced radiologists with a minimum four-week interval between assessments to ensure reliability.<\/p>\n<p><strong>Key Findings<\/strong><\/p>\n<p>The study revealed a markedly stronger correlation between patellar axial malalignment and TT-TG distance in weightbearing CBCT compared to non-weightbearing CT. These results confirm the diagnostic superiority of WR-3D in capturing the\u00a0true biomechanical behavior of the patellofemoral\u00a0joint under functional conditions.<\/p>\n<p>By reflecting quadriceps activation and realistic loading, WR-3D overcomes the\u00a0diagnostic shortcomings of traditional static imaging\u00a0and sets a new standard for evaluating patellar instability.<\/p>\n<p><strong>Future Outlook and Clinical Impact<\/strong><\/p>\n<p>This research is part of a series of clinical innovations made possible by Angell Technology\u2019s first-generation WR-3D. Building upon this foundation, Angell has continued to refine weightbearing CBCT solutions\u2014enhancing scanning range, imaging performance, and\u00a0automatic\u00a0measurements.<\/p>\n<p>Angell\u2019s\u00a0DTP580-B3 (WR-3D)\u00a0is the world\u2019s first weightbearing cone beam CT capable of full-spine and lower-limb 3D scanning and tomographic reconstruction in a standing position. It is also the only solution globally that integrates\u00a0automatic\u00a0analysis across the entire musculoskeletal chain\u2014including the spine, pelvis, hip, knee, and foot &amp; ankle\u2014bridging diagnostics and treatment planning.<\/p>\n<p>In just two years, nearly 100 WR-3D systems have been installed across China, driving adoption and clinical integration of weightbearing CBCT. Through expanded collaboration with clinical institutions, Angell aims to further broaden the clinical value and global impact of WR-3D technology, enabling truly personalized orthopaedic care.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chongqing, China \u2013\u00a0A research team from the First Affiliated Hospital of Chongqing Medical University has published a groundbreaking study in\u00a0Clinical Orthopaedics and Related Research\u00ae (CORR), highlighting the diagnostic superiority of weightbearing cone beam computed tomography (CBCT) in evaluating patellar stability. The study, titled\u00a0\u201cDecreased Association Between Patellar Axial Malalignment and Patellar Height and Increased Association Between [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1243,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[23],"tags":[],"_links":{"self":[{"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/posts\/750"}],"collection":[{"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/comments?post=750"}],"version-history":[{"count":4,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/posts\/750\/revisions"}],"predecessor-version":[{"id":1248,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/posts\/750\/revisions\/1248"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/media\/1243"}],"wp:attachment":[{"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/media?parent=750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/categories?post=750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/preview.yhct.site\/577906b9\/wp-json\/wp\/v2\/tags?post=750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}